Arc flash: prevention first, protection always

Arc flash: prevention first, protection always

An arc flash is one of the most dangerous workplace hazards – potentially causing severe burns, permanent injuries and fatalities.

In South Africa, at least one serious arc flash injury or fatality occurs monthly, particularly in high-risk sectors like mining, manufacturing, utilities and heavy industry. Understanding the risks and controls is essential for every SHEQ practitioner.

An arc flash is an electrical explosion that occurs when current travels through the air between energised conductors, or from a conductor to ground. Temperatures can soar to 20,000°C (hotter than the surface of the sun). The blast can vaporise metal, create a pressure wave strong enough to throw a person across a room and emit blinding ultraviolet light. The consequences are often catastrophic: deep burns, blindness, hearing loss or death.

Understanding the risks

Globally, thousands of arc flash incidents occur every year. A 2022 Electrical Contractor magazine article cited data suggesting arc flash causes around 7,000 burns, 2,000 hospitalisations and 400 deaths annually in the US. Arc flash can result from equipment failure, corrosion, dust, condensation, poor maintenance or accidental contact with live parts. Even equipment believed to be de-energised can pose hidden risks if it has not been properly isolated, tested or verified.

Human factors add another layer of vulnerability: complacency, rushing to meet deadlines, production pressure and gaps in communication between teams. A widely reported 2009 incident in the US illustrates this clearly. Master electrician Jason Brozen was working on an energised breaker at a hotel in Kansas when an arc flash erupted. He sustained third-degree burns on his face and arms, spent a week in a coma and remained out of work for six months.

“We chose to do energised work to reduce the hassle for the hotel,” Brozen later recalled. “I knew I needed to wear personal protective equipment (PPE) … but I chose not to do it.” His decision resulted in US$1.2 million in medical expenses and a US$65,000 OSHA fine for his employer.

Although the underlying physics of arc flash can be complex, the message is simple: it can happen anywhere electrical energy is mishandled. Recognising and mitigating the risks must be a fundamental element of every organisation’s electrical safety and SHEQ programme.

From prevention to protection: the hierarchy of controls

The National Institute for Occupational Safety and Health (NIOSH) in the US emphasises that, while PPE is essential, it is always the last line of defence. Prevention begins long before protective gear is donned. The hierarchy of controls provides a structured approach:

  1. Elimination – physically remove the hazard by de-energising equipment wherever possible.
  2. Substitution – replace outdated or unsafe equipment with safer technologies.
  3. Engineering controls – use arc-resistant switchgear, remote racking systems or isolation enclosures.
  4. Administrative controls – implement lockout-tagout, demarcated zones, live-work permits and documented safe work procedures.
  5. PPE – ensure workers wear correctly rated arc flash protective clothing and equipment.

Accurate risk assessment underpins every layer. Standards such as the Institute of Electrical and Electronics Engineers’ IEEE 1584 (“Guide for Performing Arc Flash Hazard Calculations”) and South African National Standard (SANS) 984 provide methodologies for determining incident energy levels and calculating the Arc Thermal Performance Value (ATPV) required for PPE.

Lockout-tagout processes, voltage testing and two-person verification are indispensable before any maintenance work begins. No conductor should be assumed safe until proven de-energised.

SANS 724: strengthening SA’s protection framework

The introduction of SANS 724, “Protective Clothing Against the Thermal Hazards of an Electric Arc”, marks a major milestone in South Africa’s electrical safety landscape. Aligned with global benchmarks such as NFPA 70E and IEC 61482, SANS 724 guides the selection, testing, performance requirements and maintenance of arc-rated clothing.

Importantly, SANS 724 supports employers’ obligations under the Occupational Health and Safety (OHS) Act and the Electrical Machinery Regulations 2011. These regulations require duty-holders to ensure electrical equipment is safe, appropriate PPE is provided and maintained, and workers are trained and competent to perform electrical tasks. SANS 724 and SANS 984 offer the technical depth needed to comply with these statutory duties, strengthening the link between engineering standards and legal requirements.

SANS 724 also aligns with international arc flash standards, including the International Electrotechnical Commission’s IEC 61482-1-1 (open arc test) and IEC 61482-1-2 (box test), ensuring that locally certified garments meet globally recognised performance requirements.

When prevention fails: the value of PPE

Should an arc flash occur, properly rated PPE can mean the difference between life and death. Arc-rated suits, gloves, balaclavas and face shields protect workers from intense thermal energy long enough to move to safety or avoid secondary fires. Many advanced, scientifically developed fibres and fabrics have been engineered to self-extinguish once exposed to arc heat, reducing the risk of clothing continuing to burn. By contrast, untreated cotton or synthetic garments can ignite or melt into the skin.

A wide range of solutions suitable for local climatic and operational conditions is available in South Africa:

Dromex Arc range

Made locally using Dromex’s Arc Protective Technologies (APT) fabrics, the Dromex Arc range includes PPE like the 100 Cal Arc Suit, which delivers an ATPV of 100 cal/cm². The company’s 8,000-m2 manufacturing facility in KwaZulu-Natal (KZN) is approved by the South African Bureau of Standards (SABS).

Charnaud Survive-Arc range

Manufactured at Charnaud’s Ladysmith, KZN, plant, this range comprises a “head-to-foot” range of protective wear designed for the electrical worker. The company guarantees that these garments are permanently flame-resistant for the life of the garment, and are certified to international standards. Offerings include CAT 4 Switching Gloves with an ATPV of 51.5 cal/cm2.

DuPont’s Nomex arc flash range

Nomex is a durable meta-aramid fibre with inherent fire- and heat-resistant properties that can’t be washed or worn away. Within the range, Xtreme Arc delivers an ATPV of 12 to 19 cal/cm2, with a double-faced fabric technology sacrificing the external face to protect the internal one after exposure to an arc flash.

Lenzing FR

A flame-resistant cellulosic fibre derived mainly from beech wood sourced from sustainably grown forests in Europe. Austrian firm Lenzing blends it with other high-performance fibres like aramid to deliver flame resistance and layer concepts for protective wear in electric arc protection and similar applications.

Training and safe work protocols

Training still remains the strongest defence against human error. Industry best practice includes:

  • Pre-task risk assessments and toolbox talks
  • Verification of de-energised equipment with certified testers
  • Two-person operations for high-risk switching
  • Clear communication between internal teams and contractors
  • Regular refresher training in safe electrical work practices

These low-cost, high-impact measures significantly reduce incident rates.

A shared responsibility

Electrical safety is a collective effort. Engineers, electricians, SHEQ managers, supervisors, procurement teams and contractors all play a role in ensuring that risk assessments are current, PPE meets SANS 724 requirements, safe work procedures are enforced and workers are properly trained and supervised. With proactive collaboration, the frequency and severity of arc flash incidents can be dramatically reduced, protecting both lives and livelihoods.

Published by

SHEQ Management

SHEQ MANAGEMENT is the definitive source for reliable, accurate and pertinent information to guarantee environmental health and safety in the workplace.
Prev Tackling the traffic in Cairo